• <input id="qq8kg"></input>
  • <tbody id="qq8kg"><table id="qq8kg"></table></tbody>
  • +86-13853233236  kxdandy@chinasteelstructure.cn

    CONTACT

    Add:
    No.268 Sancheng Road,Pingdu,Qingdao,
    Shandong Province,China
    Mobile:
    +86-13853233236
    Tel:
    +86-532-85397878
    Fax:
    +86-532-85397878
    E-mail:
    kxdandy@chinasteelstructure.cn

    • Name: Pre engineered steel structure workshop with Turnkey Solutiohttp

    Pre-engineered steel structure buildings (PMB) for industrial and commercial functions are a steel structures built over a structural concept of primary members, secondary members, roof and wall sheeting connected to each other and various other building components. These buildings can be provided with different structural and non-structural additions such as skylights, wall lights, turbo vents, ridge ventilators, louvers, roof monitors, doors & windows, trusses, mezzanine floors, fascias, canopies, crane systems, insulation etc., based on the customer's requirements. All the steel buildings are custom designed to be lighter in weight and high in strength. Thus steel building designs have become more flexible, durable and adaptable over the last four decades which has made steel one of the preferred materials for building construction.

    PMB/PEB's are ideal for non-residential and wide-span low-rise buildings. Some of the key advantages of PMB/PEB include economical in cost, factory controlled quality, durability, longevity, flexibility in expansion, environmentally friendly, faster installation, etc.

    Pre-engineered metal buildings are used for diverse applications such as factories, warehouses, showrooms, supermarkets, aircraft hangars, metro stations, offices, shopping malls, schools, hospitals, community buildings and many more.

    As a leading PMB/PEB manufacturer, KXD provides the complete service of engineering, fabrication and erection thus ensuring better quality control at every stage of the process.
    Pre-engineered metal buildings consists of following components:

    1. Primary Members / Main Frames
    2. Secondary Members / Cold Formed Members
    3. Roof & Wall Panels
    4. Accessories, Buyouts, Crane System, Mezzanine System, Insulation, etc.
    5. Sandwich Panels

    PRIMARY MEMBERS / MAIN FRAMES

    Primary members are the main load carrying and support members of a pre-engineered building. The main frame members include columns, rafters and other supporting members. The shape and size of these members vary based on the application and requirements. The frame is erected by bolting the end plates of connecting sections together. All the steel sections and welded plate members are designed in accordance with the applicable sections as per the latest international codes and standards such as GB and IS to meet all the customer specifications.
    LEAN TO (L-TO)

    SPAN 3
    18

    3m to 18m
     
     

    SPACE SAVER (SV)

    SPAN 6
    18

    6 m to 18 m
     
     

    L CANOPY (L-CAN)

    SPAN 3
    6

    3 m to 6 m
     
     

    BUTTERFLY CANOPY (T-CAN)

    SPAN 6
    12

    6m to 12m
     
     

    SINGLE SLOPE

    SPAN 6
    18

    6 m to 18 m
     
     

    RIGID FRAME (RF)

    SPAN 6
    96

    6 m to 96 m
     
     

    BEAM & COLUMN (BC-1)

    SPAN 24
    48

    24 m to 48 m
     
     

    BEAM & COLUMN (BC-2)

    SPAN 36
    72

    36 m to 72 m
     
     

    BEAM & COLUMN (BC-3)

    SPAN 48
    96

    48 m to 96 m
     
     

    MULTI SPAN (MS)

    SPAN 24
    120
    24 m to 120 m
     

    CRANE BEAMS

    Crane Beams are support members for different type of cranes and allow for unobstructed movement of cranes along the building length. These crane beams are supported on the columns of a building.

    MEZZANINE SYSTEMS
    Standard mezzanine system consists of profiled steel deck, mezzanine joists, built-up beams and intermediate support columns. Built-up beams span in lateral directions and mezzanine joists in longitudinal directions bolted to the top flange of beams. A concrete slab is cast on the steel deck as a finished surface. Steel checkered plates can also be used as top surface.

    TRUSSES

    KXD Truss System is one of the company's most popular and highly economical products. It is a rigid structure, ideal for large span roof systems, multiple bay buildings and as mezzanine floor framing. These structures are individually designed to meet the specific requirements of each building and are fabricated utilizing high quality efficient fixtures. The system allows for easy erection as all connections are field bolted except for field splices on very large spans, no site welding is required.
    There is possibility of significant reduction in clearances and building heights by running service pipes/ducts through the trusses. Foundation costs are also reduced due to fewer columns being required to support larger spans.

    FASCIAS AND CANOPIES
    KXD provides various types of fascias specially designed as per the customer's requirements. These can be either vertical, horizontal or with curved sheeting to enhance the architectural look of the building. Wall canopies at eaves, end wall, over doors and windows are also provided based on the requirement.

    SECONDARY MEMBERS / COLD FORMED MEMBERS

    Secondary structural framing refers to purlins, girts, eave struts, wind bracing, flange bracing, base angles, clips and other miscellaneous structural parts.
    Purlins, girts and eave struts are cold formed steel members which have a minimum yield strength of 345 MPa (50,000 psi) and will conform to the physical specifications of GB/ISO/CE or equivalent.
    PURLINS & GIRTS

    Purlins and girts are roll formed Z sections, 200 mm deep with 64 mm flanges shall have a 16 mm stiffening lip formed at 45? to the flange. They are supported on columns, rafters or building walls. They can be lapped and nested at the supports which creates a continuous beam configuration. They are placed on the roof and perimeter of the building. Hence they serve as a support to the roof sheeting and wall cladding.
    C SECTION

    C-Sections are 200 mm deep with a 100 mm flange. The flanges are perpendicular to the web and have a 24 mm stiffening lip.

    EAVE STRUT
    Eave struts are 200 mm deep with a 104 mm wide top flange, a 118 mm wide bottom flange, both are formed parallel to the roof slope. Each flange has a 24 mm stiffener lip. These are located along the sidewall; at the intersection of the planes of the roof and wall. It is constructed from cold formed C-Section and is rolled to suit the roof slope. This member transmits longitudinal wind force on the end walls from roof brace rods to wall brace rods.

    OPEN WEB JOISTS
    These are long span load carrying trusses suitable for direct support of floors and roof decks in the buildings. The system consists of crimped angles welded to the top and bottom chords.

    CABLE BRACING
    Cable bracing is made of extra high strength seven strand cable and can be designed to accommodate any length to ensure the stability of the building against forces in the longitudinal and lateral direction due to wind, cranes and earthquakes. It is made of a cable which is forged into a rod terminal and this arrangement is then fixed on a structure using a hill side washer, nut washer and a nut.

    ROOF & WALL PANELS

    KXD ROOF (KR) & KXD WALL (KW) (AVAILABLE IN ALL REGIONS)

    KXD standard steel panels are 0.3,0.4 0.5 mm or 0.6 mm thick and have a minimum yield strength of 345 MPa. Steel panels are hot dipped and galvanized with zinc or zinc-aluminium coating. Galvanized materials conform to GB for 275 grams per square meter according to GB.
    KXD panels are prepared with a multilayered coating system to ensure long life and optimum coating adherence. The base material is pretreated, before applying a corrosion resistant primer and top coat. The combined thickness of the painted film is 25 microns on the front side and 12 microns on the reverse side.

    KXD RIB / ROOF (KR)

     KXD Roof profile is strong and cost effective and was developed specifically for roofing applications. The bearing leg design permits easier installation and maintenance, supports thicker layers of insulation and allows easier curvature for a visually appealing finish.
    Coverage Area:1000 mm  
    Rib Depth:25mm

    KXD WALL (KW)

    Message Board
     
    Content:
    * Entered characters:0 Word
    Less than or equal500Character
    Posted by:
     
    Less than or equal to 20 characters (including A-Z, a-z ,0-9, Chinese characters, excluding special characters)
    Your e-mail:
    *
    Example: example@mail.com
    Telephone:
     
    Less than or equal to 32 characters (including 0-9, -, (,), comma)
    Verification code:
       
    炸金花棋牌游戏